3-4630-33

GF Signet 3-4630-33 4630 Free Chlorine Analyzer System
GF Signet 3-4630-33 4630 Chlorine Systems with Panel Materials: Black Acrylic
Description:
GF Signet 3-4630-33 4630 Chlorine Systems with Chlorine panel, free chlorine sensor (0.02 to 2 ppm) w/ sensor electronics, pH sensor w/ electronics
Price: $521400
Deprecated: base64_decode(): Passing null to parameter #1 ($string) of type string is deprecated in phar:///home/pni/wms/vendor/ProjectLibraries/WMS.phar/SingleProductAbstract.php on line 2232
Deprecated: round(): Passing null to parameter #1 ($num) of type int|float is deprecated in phar:///home/pni/wms/vendor/ProjectLibraries/WMS.phar/ProductDisplay/SingleProductTab.php on line 274
Deprecated: bcmul(): Passing null to parameter #1 ($num1) of type string is deprecated in phar:///home/pni/wms/vendor/ProjectLibraries/WMS.phar/ProductDisplay/SingleProductTab.php on line 277
Deprecated: round(): Passing null to parameter #1 ($num) of type int|float is deprecated in phar:///home/pni/wms/vendor/ProjectLibraries/WMS.phar/ProductDisplay/SingleProductTab.php on line 274
Deprecated: bcmul(): Passing null to parameter #1 ($num1) of type string is deprecated in phar:///home/pni/wms/vendor/ProjectLibraries/WMS.phar/ProductDisplay/SingleProductTab.php on line 277
Deprecated: round(): Passing null to parameter #1 ($num) of type int|float is deprecated in phar:///home/pni/wms/vendor/ProjectLibraries/WMS.phar/ProductDisplay/SingleProductTab.php on line 274
Deprecated: bcmul(): Passing null to parameter #1 ($num1) of type string is deprecated in phar:///home/pni/wms/vendor/ProjectLibraries/WMS.phar/ProductDisplay/SingleProductTab.php on line 277
The GF 4630 3-4630-33 Free Chlorine Analyzer System is an integrated all-in-one system designed to measure free chlorine. The 3-4630 Free Chlorine Analyzer with pH sensor is used to accurately calculate free chlorine in applications that have varying pH values (±0.20 pH units).
The advanced 9950-X Chlorine Controller includes a new feature called the "Chemical Guard" relay control. Because free chlorine concentration is pH dependent, the Chemical Guard feature interrupts/disables the relay that is assigned to the oxidant chemical (such as sodium hypochlorite) until the pH of the application is corrected. The 4630 series also comes complete with a flow switch that will disable the mechanical relays to the dosing pumps when the system is off or flow is interrupted to the flow cell.
The unique integrated clear flow cell accommodates the free chlorine and pH electrode, flow regulator, filter and variable area flow indicator in one compact unit. An integrated flow regulator with removable filter accepts inlet pressures of 1 to 8 bar (15 to 120 psi), while maintaining constant flow and minimal pressure to the sensors.
Water flow is controlled and directed vertically into the sensor tips eliminating the build up of air bubbles that can cause inaccurate measurement. The flow cell is also designed to maintain a minimum amount of water to ensure sensors stay submerged, even when the system and flow is turned of
The 4630 Free Chlorine Analyzer System comes complete with everything needed to support chlorine monitoring for 1 full year of operation. Panel design allows quick and easy installation and comes complete with four 4 to 20 mA outputs, flow switch with relay interrupt, four binary inputs and two mechanical relays. The 9950-X can also be used with the optional 3-9950.395-M (159 001 905) Modbus Module.
- EPA 334.0 Compliant
- Reagent free measuring
- Complete panel system allows for quick and easy installation
- Built-in flow regulator maintains constant flow and pressure to the sensors regardless of inlet pressure
- Water Distribution
- Ground Water
- Surface Water
- Gray Water Dechlorination
- Food and Beverage
- HVAC
- RO Membrane Protection
- Swimming Pools
- Aquariums
- Water Parks
- EPA 334.0 compliant
- Reagent-free measuring
- Complete panel system allows for quick and easy installation
- Built-in flow regulator maintains constant flow and pressure to the sensors
- Panel includes a 100-240 VAC power supply, two 4 to 20 mA outputs and two mechanical relays
- Optional automatic pH compensation (PPM Ranges: 0-2, 0-5 and 0-20)
- CE
- UL
- CUL
- FCC
- China RoHS
Series Data | |
Series | 4630 |
---|---|
Type | Chlorine Analyzer |
Description | Chlorine panel, free chlorine sensor (0.02 to 2 ppm) w/ sensor electronics, pH sensor w/ electronics |
Panel Materials | Black Acrylic |
Flow Cell Materials | Acrylic |
Wiring Enclosure Materials | Polycarbonate |
Flow Cell, Spacer Rings wetted Materials | Acrylic |
Flow Regulator Housing | Polycarbonate |
Strainer, E-clip, Regulator Spring, Float | Stainless Steel |
Valves, Vent | Polypropylene |
Flow Cell O-rings, Diaphragm | EPR (EPDM), FKM |
Chlorine Electrode | PVC, PTFE, FKM, Nylon, Silicone |
pH Electrode | PPS, Glass, UHMWPE, FKM |
Flow Switch | Polypropylene |
Sealing Tape on Valves, Plug and Vent | PTFE |
Plug | Polyethylene |
System Inlet Pressure Rating | 1 to 8 bar (15 to 120 psi) |
Pressure Regulator | < 0.69 bar (10 psi) variation over all ranges of flow and pressure |
Flow Tolerance | ± 15% or rated specification above |
Flow Rate Limits | 30.24 to 45.36 LPH (8 to 12 US gal/h) |
Storage Temperature | 0 to 65° C (32 to 149° F) |
Operating Temperature | 0 to 45° C (32 to 113° F) |
pH Range | 5.0 to 8.2 pH |
DC Input (3-9950-3) | 24 VDC nominal (12 to 32 VDC, ± 10% regulated), UL 60950-1 or UL 61010-1 |
AC input (9950-4) | 100 to 240 VAC. 50 to 60 Hz. 24 VA |
3-9950-X Relay Mode | Current draw up to 500 mA |
Current Loop | 12 to 32 VDC, ±10% regulated, 4 to 20 mA (30 mA max.) |
Overvoltage Protection | Protection 48 Volt Transient Protection Device. Current limiting for circuit protection.Reverse-voltage protection |
Relative Humidity | 0 to 95% |
Maximum Altitude | 4000 m (13,123 ft) |
Enclosure | NEMA 4X (with output wire glands sealed) |
Shipping Weight | 22 lb |
Standards | CE, FCC, UL, CUL, WEEE |
Approvals | China RoHS |
Product Dimensions | |
Weight | 22.00 lb |
Width | 0.00 mm, 0.00 in |
Height | 0.00 mm, 0.00 in |
Length | 0.00 mm, 0.00 in |
Document Title | Download |
---|---|
Signet Flow Switch (Spanish) | Click Here to Download |
Signet Flow Switch (German) | Click Here to Download |
Signet Flow Switch (French) | Click Here to Download |
Signet Flow Switch (English) | Click Here to Download |
Manual (Spanish) | Click Here to Download |
Manual (German) | Click Here to Download |
Manual (French) | Click Here to Download |
Manual (English) | Click Here to Download |
Datasheet Chlorine Analyzer System English | Click Here to Download |
Datasheet | Click Here to Download |
CE Certificate | Click Here to Download |
ID | Short Details | Price | |
---|---|---|---|
1220-0021 | 1220-0021 - O-ring, FKM (2 required per sensor) for Sensors by Georg Fischer | $4.00 | |
3-0700.390 | GF Signet 3-0700.390 series: 0700 *pH buff er kit (1 each 4, 7, 10 pH buff er in powder form, makes 50 ml of each) | $8.00 | |
3-2630-1 | GF Signet 3-2630-1 Amperometric Chlorine Electrode. Free Chlorine electrode, 0.02 to 2 ppm (mg/l) | $1309.00 | |
3-2630-2 | GF Signet 3-2630-2 Amperometric Chlorine Electrode. Free Chlorine electrode, 0.02 to 2 ppm (mg/l) | $1309.00 | |
3-2630-3 | GF Signet 3-2630-3 Amperometric Chlorine Electrode. Free Chlorine electrode, 0.02 to 2 ppm (mg/l) | $1309.00 | |
3-2630.391 | GF Signet 3-2630.391 Amperometric Chlorine Electrode. Free Chlorine electrode, 0.02 to 2 ppm (mg/l) | $48.00 | |
3-2630.394 | GF Signet 3-2630.394 Amperometric Chlorine Electrode. Free Chlorine electrode, 0.02 to 2 ppm (mg/l) | $156.00 | |
3-2630.398 | GF Signet 3-2630.398 Amperometric Chlorine Electrode. Free Chlorine electrode, 0.02 to 2 ppm (mg/l) | $462.00 | |
3-2632-1 | 3-2632-X Amperometric Chlorine Dioxide Electrode. MATERIAL: CPVC, MOUNTING: Signet DryLoc connection, ACCURACY: < ±3% of electrode signal after calibration, PH RANGE: 4 to 11 pH. | $1309.00 | |
3-2632.391 | Cl02 Electrolyte, 30 ml | $52.00 | |
3-2632.398 | Cl02 Maintenance Kit. PTFE | $279.00 | |
3-2650-7 | 3-2650-7 Amperometric chlorine electrode. material: pbt, accuracy: < 5 na or 1% of reading, whichever is greater, cable length: 4.6 m (15 ft) | $831.00 | |
3-2700.395 | GF Signet 3-2700.395 series: 2700 Calibration kit; includes 3 polypropylene cups, box used as cup stand, 1 pint pH 4.01, 1 pint pH 7.00 | $125.00 | |
3-2724-00 | GF Signet 3-2724-00 Flat Style PH-ORP Electrode & Sensors Temperature Element: PT1000 RTD use w/2750 preamp for S3L-4-20mA output Threaded Process Connection : NPT | ||
3-2750-7 | 3-2750-7 DryLoc pH/ORP Sensor Electronics | ||
3-2759 | GF Signet 3-2759 Series: 2759 pH/ORP System Tester Kit for all pH Instruments | $682.00 | |
3-2759.391 | GF Signet 3-2759.391 Series: 2759 Adapter Cable for use with 2751 and 2760* | $147.00 | |
3-4630.390 | Rebuild kit-screws, o-rings, boots, (1) filter screen | $180.00 | |
3-4630.391 | Pressure regulator with (1) spare filter screen | $388.00 | |
3-4630.392 | Acrylic flow cell complete with all components and connections | $2441.00 | |
3-4630.393 | Flow Switch Kit, Chlorine PP | $382.00 | |
3-9950.395-M | GF Signet 9950 Modbus Module | $486.00 | |
3822-7004 | GF Signet 3822-7004 series: 3822 *pH 4.01 buff er solution, 1 pint (473 ml) bottle | $38.00 | |
3822-7007 | GF Signet 3822-7007 series: 3822 *pH 7.00 buff er solution, 1 pint (473 ml) bottle | $38.00 | |
3822-7010 | GF Signet 3822-7010 series: 3822 *pH 10.00 buff er solution, 1 pint (473 ml) bottle | $38.00 |
Customer Questions & Answers
- Is the item durable?
- Is this item easy to use?
- What are the dimensions of this item?