3-9900-1

GF Signet 3-9900-1 Flow Multi-Parameter Controller

Signet 3-9900-XX Paddlewheel Flow Multi-Parameter Controller

Description:
Signet 3-9900-1 Flow Multi-Parameter Controller with Field Mount Transmitter Measurement Types : Flow, pH/ORP, Conductivity/Resis tivity, Salinity, Pressure, Temperature, Level, Dissolved Oxygen, Batch or user-defined (via 8058)

Item#: 159001696 | Model#: 3-9900-1 | Series#: 3-9900-XX

Price: $63700 $54145

Availability: 12 in stock. Orders received before 3:00pm Eastern Time are usually shipped same day.
$63700 $54145 /ea
Quantity

Select Options

Ships from US
select 2 to 4 items to compare.
9900 Transmitter

The Signet 9900 Transmitter provides a single channel interface for many different parameters including Flow, pH/ORP, Conductivity/Resistivity, Salinity, Pressure, Temperature, Level and other sensors that output a 4 to 20 mA signal. The 9900 Transmitter (Generation III) has the added capability of supporting the Batch Module for batching control the extra large (3.90" x 3.90") auto-sensing backlit display features "at-a-glance" visibility that can be viewed at 4-5 times the distance over traditional transmitters. The highly illuminated display and large characters reduce the risk of misreading or misinterpreting the displayed values. The display shows separate lines for units, main and secondary measurements as well as a dial-type digital bar graph.

The Signet 9900 Transmitter is offered in both panel or field mount versions. Both configurations can run on 12 to 32 power (24 VDC nominal). The 9900 can also be loop-powered with compatible sensors.

Designed for complete flexibility, plug-in modules allow the unit to easily adapt to meet changing customer needs. Optional modules include Relay, Direct Conductivity/Resistivity, H COMM, Batch, 4 to 20mA and a PC COMM configuration tool. The unit can be used with default values for quick and easy programming or can be customized with labeling, adjustable minimum and maximum dial settings, and unit and decimal measurement choices.

Fields of Application:
  • Wastewater Treatment
  • Reverse Osmosis
  • Deionization
  • Chemical Manufacturing/Addition
  • Metal and Plastic Finishing
  • Fume Scrubbers
  • Cooling Towers
  • Media Filtration
Advantages:
  • Large auto-sensing backlit display with "at-a-glance" visibility
  • "Dial-type" digital bar graph
  • Intuitive and "user-friendly" interface consistent with legacy Signet ProPoint® and ProcessPro® devices
  • Optional Field upgradable relays
  • Selectable error mode for current outputs, 3.6mA or 22mA
  • 4 to 20 mA input (with optional 8058 Signal Converter)
  • Warning LED indicator
  • Custom 13-character label capabilities for the channel type
  • Factory reset capability
Optional Plug-in Modules:
  • Relay Module
  • Direct Conductivity/Resistivity Module
  • H COMM Module
  • 4 to 20 Output Module
  • Batch Module
Standards:
  • CE
  • UL
  • CUL
  • China RoHS
  • RoHS Compliant
  • FCC
  • Lloyd's Register
Series Data
Input ChannelsOne
Input Types Digital (S3 L)Serial ASCII, TTL level, 9600 bps
Input Types Frequency Range0.5 to 1500 Hz
Input Types Frequency Accuracy0.5% of reading
Measurement TypesFlow, pH/ORP, Conductivity/Resis tivity, Salinity, Pressure, Temperature, Level, Dissolved Oxygen, Batch or user-defined (via 8058)
Case MaterialPBT
WindowShatter-resistant glass
Keypad4 buttons, injection-molded silicone rubber seal
DisplayBacklit, 7 and 14-segment
Update Rate1 s
LCD Contrast5 settings
Indicators“Dial-type” digital bar graph. LEDs for Open Collector, Relays and Warning Indicator
Enclosure Size¼ DIN
Mounting Panel¼ DIN, ribbed on four sides for panel mounting clip inside panel, silicon gasket included
Mounting Field Mounts to standard Signet field mount junction boxes. Optional angle adjustment adapter available
Mounting WallLarge enclosure (sold as an accessory) that encases the panel mount transmitter
pH0.00 to 15.00 pH
pH Temperature-99 °C to 350 °C / -146 °F to 662 °F
ORP-1999 to 1999.9 mV
Flow Rate-9999 to 99999 units per second, minute, hour or day
Totalizer0.00 to 99999999 units
Conductivity0.0000 to 99999 μS, mS, PPM and PPB (TDS), kΩ, MΩ
Conductivity Temperature-99 °C to 350 °C / –146 °F to 662 °F
Temperature-99 °C to 350 °C / –146 °F to 662 °F
Pressure-40 to 1000 psi
Level-9999 to 99999 m, cm, ft, in, %
Volume0 to 99999 cm3 , m3 , in3 , ft3 , gal, L, lb, kg, %
Salinity0 to 100 PPT
Dissolved OxygenPPM 0-50, % SAT 0-200, 0 to 999.9 TORR
Dissolved Oxygen Temperature-99 °C to 350 °C / –146 °F to 662 °F
Backlit LCD-10 °C to 70 °C / 14 °F to 158 °F
Storage Temperature -15 °C to 70 °C / 5 °F to 158 °F
Relative Humidity0 to 100% condensing for field mount; 0 to 95% non-condensing for panel mount
Maximum Altitude4,000 m (13,123 ft)
Enclosure RatingDesigned to meet NEMA 4X/IP65 (front face only on panel mount); field mount is 100% NEMA 4X/IP65
Power to Sensors Voltage+4.9 to 5.5 VDC @ 25 °C, regulated
Current1.5 mA max in loop power mode (up to 2.0 mA with 24 V @ 300 Ω max. loop impedance); 20 mA max when using DC power
Short CircuitProtected
IsolationLow voltage (< 48V AC/DC) to loop with DC power connected
Terminal Blocks Pluggable screw type14 AWG max wire gauge
Input Power DC10.8 to 35.2 VDC, regulated
9900 without Relay Module200 mA @ 10.8 VDC to 35.2 VDC
9900 with Relay Module300 mA @ 10.8 VDC to 35.2 VDC
Overvoltage Protection48 Volt Transient Protection Device
No DC Power Input Max. Loop Impedance50 Ω @ 12 V, 325 Ω @ 18 V, 600 Ω @ 24 V
With DC Power Input or with 2nd loop, all the time Max. Loop Impedance250 Ω @ 12 V, 500 Ω @ 18 V, 750 Ω @ 24 V
Relay Specifications TypeDry-Contact Relays (2):SPDT, Open Collector (1): N/A
Relay Specifications FormDry-Contact Relays (2):C, Open Collector (1): N/A
Max. Current RatingDry-Contact Relays (2):5 A resistive, Open Collector (1): 50 mA DC
Max. Voltage RatingDry-Contact Relays (2):30 VDC or 250 VAC, Open Collector (1): 30 VDC
Hysteresis Adjustable (absolute in engineering units) (EUs)
LatchReset in test screen only
Delay 9999.9 seconds (max.)
Test ModeSet On or Off
Cycle Time99999 seconds (max.)
Maximum Pulse Rate300 pulses/minute
Proportional Pulse400 pulses/minute
Volumetric Pulse Width0.1 to 3200 s
Pulse Width Modulation0.1 to 320 s
Input TypesDigital (S3 L) or AC frequency
Input Specifications Digital (S3 L)Serial ACSII, TTL level, 9600 bps
Frequency Input Sensitivity80 mV @ 5 Hz, gradually increasing with frequency
Frequency Input Span0.5 Hz to 1500 Hz @ TTL level input
Frequency Input Accuracy± 0.5% or reading max error @ 25 °C
Frequency Input Resolution 1 μS
Frequency Input Repeatability± 0.2% of reading
Power Supply Rejection±1 μA per volt
Power Supply Short CircuitProtected
Update Rate(1/frequency) + 150 ms
Current Loop Output StandardANSI-ISA 50.00.01 Class H
Current Output4 to 20 mA, isolated, fully adjustable and reversible
Span3.8 to 21 mA
Zero4.0 mA factory set; user programmable from 3.8 to 5.0 mA
Full Scale20.00 mA factory set; user programmable from 19.0 to 21.0 mA
Accuracy±32 μA max. error @ 25 °C @ 24 VDC
Resolution6 μA or better
Temperature Drift±1 μA per °C
Power Supply Rejection ±1 μA per V
IsolationLow voltage (< 48 VAC/DC)
Voltage12 to 32 VDC ±10%
Max. Impedance (with DC power input)250 Ω @ 12 VDC / 500 Ω @ 18 VDC / 750 Ω @ 24 VDC
Max. Impedance (no DC power input)50 Ω @ 12 VDC / 325 Ω @ 18 VDC / 600 Ω @ 24 VDC
Update Rate150 mS nominal
Adjustable SpanReversible
Error ConditionSelectable error condition 3.6 or 22 mA
Test ModeIncrement to desired current (range 3.8 to 21.00 mA
Open Collector Output50 mA DC max., 30 VDC
Product Dimensions
Weight1.39 lb
Width160.00 mm, 6.30 in
Height80.00 mm, 3.15 in
Length260.00 mm, 10.24 in
Document TitleDownload
CE CertificateClick Here to Download
DatasheetClick Here to Download
IDShort DetailsPrice 
3-0251PC COMM configuration tool$0.00
3-8050GF Signet 3-8050 UniversalMountingKit$73.00
3-8050.396RC filter kit, (2) filters, for relay use$88.00
3-80513-8051 GF Signet Integral mount kit, for flow sensors, Yellow Valox nut$73.00
3-8051-1Integral mount kit, for flow sensors, PP$85.00
3-8051-2Integral mount kit, for flow sensors, PVDF$107.00$99.84
3-8052Integral mount kit, for cond/resis sensors, 3/4in NPT thread$83.00
3-8058-13-8058-X i-Go 8058 Signal Converter$280.00
3-8058-23-8058-X i-Go 8058 Signal Converter$416.00$243.46
3-9000.392-1Liquid tight connector, (1) NPT connector$28.00
3-9900.390Standard connector kit, right angle$52.00
3-9900.391Optional connector kit, in-line$105.00
3-9900.392Wall mount accessory kit$222.00
3-9900.396Angle adjustment adapter kit, for field mount 9900$31.00
6682-0204Cond/Resis module plug, 4-terminals, right angle$26.00
6682-1102DC power plug, 2-terminals, right angle$21.00
6682-1103Relay module plug, 3-terminals, right angle$21.00
6682-1104Loop power plug, 4-terminals, right angle$26.00
6682-3004Terminal block plug$52.00
6682-3104Freq/S3L input plug, 4-terminals, right angle$26.00
7310-10247310-XX24 7310 Switching Power Supplies$122.00
7310-20247310-XX24 7310 Switching Power Supplies$163.00
7310-40247310-XX24 7310 Switching Power Supplies$191.00
7310-60247310-XX24 7310 Switching Power Supplies$286.00
7310-70247310-XX24 7310 Switching Power Supplies$369.00


 

 

 

Customer Questions & Answers

Don't see what you're looking for? Ask the Community
Searching for relevant results...
Typical questions asked about products:
  • Is the item durable?
  • Is this item easy to use?
  • What are the dimensions of this item?

Customer Reviews

1 Star
0%
2 Star
0%
3 Star
0%
4 Star
0%
5 Star
0%