US06-0011-01

Flowline US06-0011-01 US06 Reflective Ultrasonic Liquid & Solids Level Sensor Transmitter
Reflective US06 Ultrasonic Liquid & Solids Level Sensor Transmitter of Flowline with Material PVDF
Description:
Flowline US06-0011-01 Reflective Ultrasonic Liquid & Solids Level Sensor Transmitter, 8" to 19.6' (20cm to 6m), 4-20mA or 20-4mA
Price: $106500
Deprecated: base64_decode(): Passing null to parameter #1 ($string) of type string is deprecated in phar:///home/pni/wms/vendor/ProjectLibraries/WMS.phar/SingleProductAbstract.php on line 2232
Deprecated: round(): Passing null to parameter #1 ($num) of type int|float is deprecated in phar:///home/pni/wms/vendor/ProjectLibraries/WMS.phar/ProductDisplay/SingleProductTab.php on line 274
Deprecated: round(): Passing null to parameter #1 ($num) of type int|float is deprecated in phar:///home/pni/wms/vendor/ProjectLibraries/WMS.phar/ProductDisplay/SingleProductTab.php on line 274
Deprecated: bcmul(): Passing null to parameter #1 ($num1) of type string is deprecated in phar:///home/pni/wms/vendor/ProjectLibraries/WMS.phar/ProductDisplay/SingleProductTab.php on line 277
Deprecated: round(): Passing null to parameter #1 ($num) of type int|float is deprecated in phar:///home/pni/wms/vendor/ProjectLibraries/WMS.phar/ProductDisplay/SingleProductTab.php on line 274
Deprecated: round(): Passing null to parameter #1 ($num) of type int|float is deprecated in phar:///home/pni/wms/vendor/ProjectLibraries/WMS.phar/ProductDisplay/SingleProductTab.php on line 274
Deprecated: bcmul(): Passing null to parameter #1 ($num1) of type string is deprecated in phar:///home/pni/wms/vendor/ProjectLibraries/WMS.phar/ProductDisplay/SingleProductTab.php on line 277
Deprecated: round(): Passing null to parameter #1 ($num) of type int|float is deprecated in phar:///home/pni/wms/vendor/ProjectLibraries/WMS.phar/ProductDisplay/SingleProductTab.php on line 274
Deprecated: round(): Passing null to parameter #1 ($num) of type int|float is deprecated in phar:///home/pni/wms/vendor/ProjectLibraries/WMS.phar/ProductDisplay/SingleProductTab.php on line 274
Deprecated: bcmul(): Passing null to parameter #1 ($num1) of type string is deprecated in phar:///home/pni/wms/vendor/ProjectLibraries/WMS.phar/ProductDisplay/SingleProductTab.php on line 277
Deprecated: round(): Passing null to parameter #1 ($num) of type int|float is deprecated in phar:///home/pni/wms/vendor/ProjectLibraries/WMS.phar/ProductDisplay/SingleProductTab.php on line 274
Deprecated: round(): Passing null to parameter #1 ($num) of type int|float is deprecated in phar:///home/pni/wms/vendor/ProjectLibraries/WMS.phar/ProductDisplay/SingleProductTab.php on line 274
Deprecated: bcmul(): Passing null to parameter #1 ($num1) of type string is deprecated in phar:///home/pni/wms/vendor/ProjectLibraries/WMS.phar/ProductDisplay/SingleProductTab.php on line 277
The intrinsically safe reflective ultrasonic level transmitter provides continuous level measurement up to 39.3' (12m) with a 4-20 mA analog signal output, and is configured via its integral push button display module or WebCal software. The non-contact liquid level sensor features our proprietary Reflective Technology™ that delivers reliable level measurement in condensing environments. Select this sensor for bulk tanks with non-foaming and mildly vaporous media such as chemicals, water, wastewater and oil. Typical applications include bulk storage, neutralization tank, clarifier and waste sumps.
FEATURES:- Offered in 6m (19.6') and 12m (39.3') measurement ranges
- Reflective Technology measures reliably with condensation
- Corrosion resistant PVDF transducer with aluminum enclosure
- Narrow 3" (7.6cm) beam width for applications with limited space
- LCD display indicates level in inches, meters or percent of span
- Fail-safe diagnostics with selectable fail-safe signal outputs
- Configuration via push button display or WebCal software
- Automatic temperature compensation from -40° to 80° C.
Condensation is the most common variable in liquid level applications. Condensation attenuates the acoustic signal of ultrasonic sensors with horizontal transducers, weakening their signal strength and signal to noise ratio by up to 50%, and substantially reducing their measurement reliability. At the core of Reflective Technology™ is a simple fact. Unlike flat horizontal surfaces, significant water droplets cannot adhere to smooth vertical surfaces. By orienting the transducer vertically, condensation runs off the transducer and does not affect sensor performance. The unimpeded transmit and receive signals are redirected to and from the liquid off a 45° reflector, delivering reliable level measurement. Thanks gravity.
The intrinsically safe reflective ultrasonic level transmitter provides continuous level measurement up to 39.3' (12m) with a 4-20 mA analog signal output, and is configured via its integral push button display module or WebCal software. The non-contact liquid level sensor features our proprietary Reflective Technology™ that delivers reliable level measurement in condensing environments. Select this sensor for bulk tanks with non-foaming and mildly vaporous media such as chemicals, water, wastewater and oil. Typical applications include bulk storage, neutralization tank, clarifier and waste sumps.
FEATURES:- Offered in 6m (19.6') and 12m (39.3') measurement ranges
- Reflective Technology measures reliably with condensation
- Corrosion resistant PVDF transducer with aluminum enclosure
- Narrow 3" (7.6cm) beam width for applications with limited space
- LCD display indicates level in inches, meters or percent of span
- Fail-safe diagnostics with selectable fail-safe signal outputs
- Configuration via push button display or WebCal software
- Automatic temperature compensation from -40° to 80° C.
Condensation is the most common variable in liquid level applications. Condensation attenuates the acoustic signal of ultrasonic sensors with horizontal transducers, weakening their signal strength and signal to noise ratio by up to 50%, and substantially reducing their measurement reliability. At the core of Reflective Technology™ is a simple fact. Unlike flat horizontal surfaces, significant water droplets cannot adhere to smooth vertical surfaces. By orienting the transducer vertically, condensation runs off the transducer and does not affect sensor performance. The unimpeded transmit and receive signals are redirected to and from the liquid off a 45° reflector, delivering reliable level measurement. Thanks gravity.
_x000D_ The intrinsically safe reflective ultrasonic level transmitter provides continuous level measurement up to 39.3' (12m) with a 4-20 mA analog signal output, and is configured via its integral push button display module or WebCal software. The non-contact liquid level sensor features our proprietary Reflective Technology™ that delivers reliable level measurement in condensing environments. Select this sensor for bulk tanks with non-foaming and mildly vaporous media such as chemicals, water, wastewater and oil. Typical applications include bulk storage, neutralization tank, clarifier and waste sumps._x000D_
_x000D_ FEATURES:_x000D_- _x000D_
- Offered in 6m (19.6') and 12m (39.3') measurement ranges _x000D_
- Reflective Technology™ measures reliably with condensation _x000D_
- Corrosion resistant PVDF transducer with aluminum enclosure _x000D_
- Narrow 3" (7.6cm) beam width for applications with limited space _x000D_
- LCD display indicates level in inches, meters or percent of span _x000D_
- Fail-safe diagnostics with selectable fail-safe signal outputs _x000D_
- Configuration via push button display or WebCal software _x000D_
- Automatic temperature compensation from -40° to 80° C. _x000D_
Condensation is the most common variable in liquid level applications. Condensation attenuates the acoustic signal of ultrasonic sensors with horizontal transducers, weakening their signal strength and signal to noise ratio by up to 50%, and substantially reducing their measurement reliability. At the core of Reflective Technology™ is a simple fact. Unlike flat horizontal surfaces, significant water droplets cannot adhere to smooth vertical surfaces. By orienting the transducer vertically, condensation runs off the transducer and does not affect sensor performance. The unimpeded transmit and receive signals are redirected to and from the liquid off a 45° reflector, delivering reliable level measurement. Thanks gravity.
_x000D_Series Data | |
Series | US06 |
---|---|
Range | 8" to 19.6' (20cm to 6m) |
Accuracy | ± 0.2% of range |
Resolution | 0.079" (2mm) |
Dead band | 8" (20.3cm) |
Beam width | 3" (7.6cm) |
Configuration | Push button or WebCal ® PC Windows ® USB ® 2.0 |
Memory | Non-volatile |
Display type | LCD, 6-digit |
Display units | Inch, cm or percent |
Supply voltage | 14-28 VDC |
Loop resistance | 500 ohms @ 24 VDC |
Signal output | 4-20mA, two-wire |
Signal invert | 4-20mA or 20-4mA |
Signal fail-safe | 4mA, 20mA, 21mA, 22mA, hold last value |
Process temp. | F: -40°Â to 176°, C: -40° to 80° |
Temp. comp. | Automatic |
Ambient temp. | F: -40°Â to 176°, C: -40° to 80° |
Pressure | 30 psi (2 bar) |
Enclosure rating | Type 4X (IP66) |
Encl. material | Aluminum |
Enclosure vent | Water tight membrane |
Conduit entrance | 1/2" NPT |
Transducer type | Reflective |
Transducer mat. | Polyvinylidene fluoride |
Process mount | 06-0001: 2" NPT, 06-0011: 2" G, 12-0001: 3" NPT, 12-0011: 3" G |
Mount gasket | -0001: N/a, -0011: Viton® |
Classification | Intrinsically safe |
Approvals | CSA for Canada: Class I, Division 1, Groups A, B, C and D T4; Class II, Division 1, Groups E, F and G T4; Class III, T135C; Ex ia IIC T4 Ga; Ex ia IIIC, T135C Da; CSA for U.S.: Class I, Division 1, Groups A, B, C and D T4; Class II, Division 1, Groups E, F and G T4; Class III, T135C; Class I, Zone 0, IIC AEx ia T4 Ga; Class II, Zone 20, IIC AEx ia, T135C Da |
Entity parameters | Install per control drawing #600820 |
Power & Return | 2-pin quick connect terminal block |
WebCal Connect. | 2-pin quick connect terminal block |
Display Connect. | 5-pin plug and socket |
Compliance | CE, RoHS |
Product Dimensions | |
Weight | 0.00 lb |
Width | 74.20 mm, 2.92 in |
Height | 165.10 mm, 6.50 in |
Length | 0.00 mm, 0.00 in |
Document Title | Download |
---|---|
Brochure | Click Here to Download |
Control Drawing | Click Here to Download |
CSA Certificate | Click Here to Download |
Data Sheet | Click Here to Download |
IECEx Certificate | Click Here to Download |
Manual | Click Here to Download |
Quick Start | Click Here to Download |